Description

Function Emergency stop module / safety gate monitor
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s
Thermal current Ith max. 7 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Removable terminals +
Width 22,5 mm
Type BG 5925/920
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 to connect:- magnetic switch NE 5020- magnetic switch NE 5021 Output: max. 3 NO contacts, see contacts 2-channel operation Line fault detection on On-button Manual restart or automatic restart, switch S2 Cross fault monitoring LED indicator for state of operation LED indicator for channel 1 and 2 Optionally with fast Auto start Removable terminal strips Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 Width 22.5 mm''